Blog

[FNS-28] FusionAnalytics 1.0.3 Release Notes

Description


FusionAnalytics Rev. 1.0.3


RELEASE NOTES

Status: 26-07-2012

Welcome to FusionAnalytics !

We appreciate your feedback. Please use the web form or send mail to:

These Release Notes describe what is contained in this release, provide
late-breaking news, and list additional documentation for the software.

For additional information on FusionAnalytics, please visit our website at:

https://www.fusion-analytics.com

The help for this product is now online, where it can be constantly updated
and refreshed. You can find it here:

https://intergral.atlassian.net/wiki/

For known issues and further support, please see the following web pages:

https://www.fusion-analytics.com/fa/faq.cfm
https://www.fusion-analytics.com/fa/support.cfm

———————————————–

RESOLVED ISSUES 1.0.3

Key Issue Type Summary
FN-2320 New Feature DailyStatus and TAP reports should support selecting email recipients via a configuration page, similar to SLA
FN-2288 Improvement Improve import performance when importing a large number of files
FN-2298 Improvement Add a job to rebuild indices for table UPLOADEDFILES every few minutes
FN-2318 Improvement Add support for IPv6
FN-2332 Improvement Upgrade JVM to latest version
FN-2291 Bug FADS EMail settings: adding multiple email addresses (separated by commas) doesn’t work
FN-2294 Bug Uploading a corrupted file can make the import hang
FN-2316 Bug ‘Update Request Status’ job fails with DB ‘String or binary data would be truncated’ error message
FN-2317 Bug FADC stops importing files
FN-2319 Bug Editing application task, with incorrect data adds new task
FN-2321 Bug FADC EMail Settings: adding multiple email addresses (separated my commas) doesn’t work
FN-2322 Bug FADC not processing all files in the import folder
FN-2323 Bug ‘Files waiting’ is incremented for suitable but empty files
FN-2327 Bug FADC runs out of heap space when processing files with very long lines
FN-2331 Bug onImportFile script script can cause a DB deadlock when attempting to delete data

Issue Details

Type: Technote
Issue Number: FNS-28
Components: Setup
Environment:
Resolution: Fixed
Added: 18/07/2012 08:46:31
Affects Version: 1.0.3
Fixed Version: 1.0.3
Server:
Platform:
Related Issues:
  • FNS-22 – FusionAnalytics 1.0.1 Release Notes
  • FNS-26 – FusionAnalytics 1.0.2 Release Notes
  • FNS-29 – FusionAnalytics 1.0.4 Release Notes

[FNS-22] FusionAnalytics 1.0.1 Release Notes

Description


FusionAnalytics Rev. 1.0.1


RELEASE NOTES

Status: 29-11-2011

Welcome to FusionAnalytics !

We appreciate your feedback. Please use the web form or send mail to:

These Release Notes describe what is contained in this release, provide
late-breaking news, and list additional documentation for the software.

For additional information on FusionAnalytics, please visit our website at:

https://www.fusion-analytics.com

The help for this product is now online, where it can be constantly updated
and refreshed. You can find it here:

https://intergral.atlassian.net/wiki/

For known issues and further support, please see the following web pages:

https://www.fusion-analytics.com/fa/faq.cfm
https://www.fusion-analytics.com/fa/support.cfm

———————————————–

RESOLVED ISSUES 1.0.1

Key Issue Type Summary
FN-2147 New Feature Upgrade functionality for DCML applications
FN-2158 New Feature FusionAnalytics 1.0.1 Setup
FN-2148 Improvement Update Index and Stats reports insufficient permissions
FN-2166 Improvement APML application should pass the Server-ID to the extension points
FN-2168 Improvement Basic IP Address views
FN-2170 Improvement Enable the Archived Logfiles Management per default
FN-2174 Improvement Update help links
FN-2149 Bug Data truncation errors
FN-2151 Bug Unexpected parameter order while importing data
FN-2155 Bug Invalid log message about truncated value
FN-2156 Bug DCML field misalignment in CRASHPROTECTION table
FN-2172 Bug “String or binary data would be truncated” error when importing fadc log files
FN-2176 Bug Horizontal Axis labels rendering backwards
FN-2177 Bug TBC within accordion hangs at 67%

Issue Details

Type: Technote
Issue Number: FNS-22
Components: Setup
Environment:
Resolution: Fixed
Added: 23/11/2011 21:47:10
Affects Version: 1.0.1
Fixed Version: 1.0.1
Server:
Platform:
Related Issues:
  • FNS-26 – FusionAnalytics 1.0.2 Release Notes
  • FNS-28 – FusionAnalytics 1.0.3 Release Notes
  • FNS-9 – FusionAnalytics 1.0.0 Release Notes

[FNS-26] FusionAnalytics 1.0.2 Release Notes

Description


FusionAnalytics Rev. 1.0.2


RELEASE NOTES

Status: 24-04-2012

Welcome to FusionAnalytics !

We appreciate your feedback. Please use the web form or send mail to:

These Release Notes describe what is contained in this release, provide
late-breaking news, and list additional documentation for the software.

For additional information on FusionAnalytics, please visit our website at:

https://www.fusion-analytics.com

The help for this product is now online, where it can be constantly updated
and refreshed. You can find it here:

https://intergral.atlassian.net/wiki/

For known issues and further support, please see the following web pages:

https://www.fusion-analytics.com/fa/faq.cfm
https://www.fusion-analytics.com/fa/support.cfm

———————————————–

RESOLVED ISSUES 1.0.2

Key Issue Type Summary
FN-2143 New Feature Simplified SLA report
FN-2163 New Feature Implement upgrade functionality for DCML applications
FN-2191 New Feature Provide upgrade functionality for (1.0.0 – 1.0.6) to 1.0.7
FN-1044 Improvement Toughen rebuild/reorganize/update statistics job error recovery procedure
FN-1278 Improvement Add ‘SQL Connection Test’ string to datasources
FN-2130 Improvement Refactor FALM to use NIO
FN-2131 Improvement Increase default trial period from 10 to 30 days
FN-2146 Improvement Reject data coming over the REST interface if there is not enough disk space left
FN-2148 Improvement Update Index and Stats reports insufficient permissions
FN-2150 Improvement FADC should handle out of disk space situations before they actually cause problems
FN-2157 Improvement Enable the Archived Logfiles Management per default
FN-2160 Improvement APML application should pass the Server-ID to the extension points
FN-2161 Improvement Basic IP Address views
FN-2169 Improvement Better handling of pending imports
FN-2183 Improvement Upgrade Setup to latest version of install4j
FN-2185 Improvement Report creation for historic data
FN-2188 Improvement Make sure that the UPLOADEDFILES table only contains entries for files that have been uploaded correctly
FN-2194 Improvement Update JVM to 7u2
FN-2243 Improvement The size of the CLIENTIP column should be increased so that IP6 addresses can be stored
FN-2276 Improvement ‘Setting’ link in top right corner should be removed
FN-2277 Improvement Remove uneccesary warning messages from cleanupProperties script
FN-2279 Improvement Remove unnecessary files
FN-2088 Bug The FA keygen doesn’t work on Share*IT
FN-2116 Bug The Update Index and Stats job reports errors for each table it attempts to organise
FN-2123 Bug TAP reports causing ClassCastException and chain of errors
FN-2125 Bug Horizontal Axis labels rendering backwards
FN-2126 Bug TBC within accordion hangs at 67%
FN-2129 Bug When uploading an application the database type is not updated as defined on the configuration page
FN-2135 Bug Timeline components showing wrong month
FN-2139 Bug Manage the archive logs fails with FADCProgramException
FN-2145 Bug FADS will not use the files in the [app-name]-upgrade folder until the application is restarted
FN-2155 Bug Invalid log message about truncated value
FN-2159 Bug Activation lost after system ran out of disk space
FN-2162 Bug Unexpected parameter order while importing data
FN-2164 Bug Data truncation errors
FN-2165 Bug DCML field misalignment in CRASHPROTECTION table
FN-2167 Bug apps-server.jsp contains DNA code that should be removed
FN-2173 Bug “String or binary data would be truncated” error when importing certain fadc log files
FN-2179 Bug Cannot establish connection to MSSQL
FN-2180 Bug Archived Logfiles Management cannot cope with corrupt ZIPs
FN-2184 Bug Button should change to ‘Stop’ when manually executing a job
FN-2186 Bug ERROR [com.intergral.fusionanalytics.dc.config.DirectoryObserver2] An unexpected error occurred: Java heap space
FN-2190 Bug FADC reschedules files that have been already imported
FN-2193 Bug Activation period can get lost if FADC is started with a large number of files located in the import directories
FN-2195 Bug Incorrect positioning of Disk Usage message
FN-2196 Bug Data Volume Management job does not complete (in acceptable time)
FN-2197 Bug Annotation markers on overview screen are at wrong time
FN-2199 Bug [Application Scheduled Tasks] event.layerX and event.layerY are broken and deprecated in WebKit
FN-2200 Bug All data input on SLA Report Configuration must be validated
FN-2201 Bug Arrange “Add From Users” list in SLA Report Configuration case-sensitive alphanumerically
FN-2202 Bug SLA Report Configuration should allow the user to select between a 5-day and 7-day week
FN-2203 Bug Fail/success prefix in SLA email subject should come after [fusionanalytics]
FN-2204 Bug SLA Report Configuration should allow the user to choose custom title to replace “SLA Report for”, and should use report name if one isn’t present
FN-2205 Bug SLA Report general fields should be reworded to be understandable to business customers
FN-2206 Bug SLA Report general data does not match breakdown data
FN-2207 Bug Previous Values on the SLA report should be implemented
FN-2208 Bug Average Request Execution Time in Domain Breakdown on the SLA Report should show units (ms)
FN-2209 Bug SLA Report status codes should be ordered numerically
FN-2210 Bug SLA Report status codes should include a description of what they are
FN-2211 Bug SLA Report main title should be wrapped properly when the title is longer than the 6-block box and start/time do not need hh:mm
FN-2212 Bug SLA Report general data block should be re-arranged to show matching pairs
FN-2213 Bug Outages crossing the midnight boundary are not displayed on SLA reports
FN-2214 Bug Create and add icons to SLA Report Configuration
FN-2215 Bug SLA Report needs updated icons for correct/incorrect thresholds
FN-2216 Bug SLA Report Configuration Rename and Copy buttons are not functional
FN-2218 Bug SLA Report general data blocks have uneven widths
FN-2219 Bug SLA thresholds do not allow blank values
FN-2220 Bug Update Request Status logs an ArithmeticException if the request table is empty
FN-2221 Bug Previous percentage on SLA Report should be formatted as percentage and should show 100% instead of 100.0%
FN-2222 Bug Time allowed for an outage to be considered a real midnight-crossing outage should be increased to 7.5 seconds
FN-2223 Bug Global average execution time should be calculated from total requests instead of average of averages from domains
FN-2224 Bug Tooltips should be added to any components in the SLA Report configuration that need a description
FN-2225 Bug Custom email fields in SLA Report configuration should be increased
FN-2226 Bug Weekly report options should be changed to display the days they will run, and Sunday to Sunday should be added
FN-2227 Bug SLA Report configuration tabs should have blue text when hovered instead of white
FN-2228 Bug Add From Users table in SLA Report configuration should be longer and match the width of the custom email fields
FN-2229 Bug Custom email title field in SLA Report configuration should be 50% longer
FN-2230 Bug Quarterly option should be removed from SLA Report configuration for this release
FN-2231 Bug Threshold values on SLA Report Configuration should be aligned right
FN-2232 Bug Disable threshold target field if not enabled on SLA Report configuration
FN-2233 Bug Fix threshold description text on SLA Report Configuration
FN-2234 Bug Threshold default values should be added to SLA Report configuration
FN-2235 Bug If no threshold is defined for the SLA Report, show “No target defined” in target field instead of hiding it
FN-2236 Bug A threshold without an enabled target on the SLA Report should show the grey icon instead of the tick
FN-2237 Bug “View in Analytics” link for status codes should be removed and replaced with percentage column
FN-2238 Bug “Investigate” link in SLA Report for outages should be implemented
FN-2239 Bug Bracers in Add From Users table on SLA Report configuration should not show empty brackets if no email address is configured
FN-2240 Bug SLA Report Configuration threshold tab should show that those are daily thresholds
FN-2241 Bug Previous Values on the SLA report use 7-day thresholds when 5-day week is selected
FN-2244 Bug Usernames that are not url-friendly cause issues in the Add From Users table in SLA Report Configuration
FN-2245 Bug Placemark grouping problem
FN-2247 Bug Previous and Target fields on SLA Report are not aligned
FN-2248 Bug FusionAnalytics server (FADS & FADC) does not appear to open in IE 64bit
FN-2249 Bug Using Ajax to reload sections of the configuration page causes rendering issues in other areas
FN-2250 Bug Add final interface tweaks for SLA Report Configuration
FN-2251 Bug Add final appearance tweaks to SLA Report
FN-2252 Bug The target number for the “Number of outages should not exceed” is not saved correctly
FN-2253 Bug Errors in FADC application uploads cause upload dialog and different errors to be displayed
FN-2254 Bug Duplicate user error in either FADS or SLA
FN-2255 Bug SLA Reports Dates are in German (local timezone)
FN-2256 Bug All threshold icons in the SLA Report Configuration have the same tooltip
FN-2257 Bug Incomplete exception/error messaging when upgrading an application in FADS
FN-2258 Bug FADS Application upgrade problems until server restart
FN-2260 Bug Data Volume Management job uses DBTIMEFROM instead of DT column when deleting data from the JDBC table
FN-2261 Bug If both an ongoing midnight-outage and non-midnight outage exist on one report, the ongoing outage will use the duration of the total downtime
FN-2265 Bug Outages on SLA Report should be listed in the order they occurred
FN-2266 Bug SLA Report should not show in “Reports” as only email implementation will be in this release
FN-2267 Bug Error when attempting to parse a request URL written in short format
FN-2270 Bug Report configurations with the dot character cannot be configured
FN-2273 Bug Daylight savings caused SLA report to run for the day before it was supposed to if clocks were changed
FN-2274 Bug Runtime Information occasionally shows wrong number of processing files
FN-2280 Bug Help links “What is T.A.P?” in TAP report are incorrect and pointing to the wrong documentation version
FN-2282 Bug Daily and weekly won’t run together
FN-2283 Bug Monthly report does not run correctly
FN-2284 Bug Monthly outage target displays as 0E-10
FN-2286 Bug Default prefix should be added to SLA report email heading when one or more targets were not met
FN-2287 Bug Uptime target on SLA Report shows 100% if target is 99.001% or higher
FN-2292 Bug Duplicate TAP entries in TAP table
FN-2293 Bug FADC displays 00:59:50 as starting time for imports that are about to start
FN-2294 Bug Uploading a bogus file can make the import hang
FN-2297 Bug Stopping all DataCollectors also stops currently executing jobs
FN-2300 Bug Stopping an application while archives are unpacked in the background can result in wrong value for waiting archives
FN-2301 Bug Import performance degradation when doing bulk imports

Issue Details

Type: Technote
Issue Number: FNS-26
Components: Setup
Environment:
Resolution: Fixed
Added: 22/03/2012 14:30:08
Affects Version: 1.0.2
Fixed Version: 1.0.2
Server:
Platform:
Related Issues:
  • FNS-22 – FusionAnalytics 1.0.1 Release Notes
  • FNS-28 – FusionAnalytics 1.0.3 Release Notes

[FNS-11] FusionAnalytics DataServices: Application Refresh

Description

To aid development of DataServices applications (DSAPPs), the FusionAnalytics DataServices server (FADS) File Watcher watches specific files and folders, and restarts the associated DSAPP when it detects changes.

The File Watcher watches the APML folder (named by the APML configuration element), and all subfolders of that folder. This ticket details the conditions under which FADS will restart a DSAPP.

The following are the conditions which, when met, will cause FADS to stop and restart a DSAPP.

  1. Any change to APML (Application Provider Markup Language) grammar files
    • These are the XML description of a DSAPP, usually with the extension .apml, .dp, and containing Module XML root element.
  2. Any change to the number of files (not just APML) in the watched folder.


Changes to Data Provider programs (usually written in Groovy) will not explicitly cause a restart, although the addition or removal of a DP program file will (due to rule 2 above).

Issue Details

Type: Technote
Issue Number: FNS-11
Components: Data Services
Environment:
Resolution: Fixed
Added: 08/09/2011 11:54:47
Affects Version:
Fixed Version: 1.0.0
Server:
Platform:
Related Issues: None

[FNS-27] How do I change the location of the database / datasource in FusionAnalytics

Description

Requirement

You want to change the location of the database to a different server/port/URL/DBMS/etc.

Background

FusionAnalytics is made up of two main server-side components – the DataCollector and DataServices. The DataCollector deals with importing and quantizing data. The DataServices deals with running reports and serving data to the UI clients.

Resolution

Currently, the two server-side elements manage their DB connection configuration independently. Therefore, there are two configuration updates to make when the DB connection details change.

Issue Details

Type: Technote
Issue Number: FNS-27
Components: Data Services
Environment:
Resolution: Fixed
Added: 26/04/2012 10:16:42
Affects Version: 1.0.2
Fixed Version: 1.0.2
Server:
Platform:
Related Issues: None

[FNS-24] FusionAnalytics (FADS & FADC) does not appear to open in Internet Explorer 64bit

Description

The root (index) page of the FusionAnalytics Server does not show in Internet Explorer 64bit. Only a blank / white (empty) page is shown.

To fix this issue, the security setting in Internet Explorer (64bit) that prevents Meta Tag Refresh called “Meta Tag Refresh” should be enabled. If this setting is disabled then the refresh from the FusionAnalytics root page will be prevented!

The setting can be found under the …

  • Security tab > Custom Level > Miscellaneous
    … and the Meta Tag Refresh should be listed. If this is disabled, please enable it as it will stop the meta refresh from working.

Note: Aside from being able to disable it selectively, it is automatically disabled if you set IE’s security level to ‘High’ [observed in IE9].

Issue Details

Type: Technote
Issue Number: FNS-24
Components: Data Services
Environment: Windows, Internet Explorer 64bit
Resolution: Fixed
Added: 14/03/2012 13:59:22
Affects Version: 1.0.1
Fixed Version: 1.0.2
Server:
Platform:
Related Issues: None

[FNS-1] Creating Daily Status Reports in FusionAnalytics

Description

Creating Daily Status Reports in FusionAnalytics

INTRODUCTION

A major new feature in the release candidate is the addition of a Daily Status Report.This report contains a breakdown of the server’s performance on the previous day including detailed information about the requests, database activity, resource usage and even a breakdown of individual applications running. The report can be scheduled to be emailed every day to a number of users. Details on how to setup and configure the Daily Reports can be found in the article below.

1.0 SETUP

1.1 USERS

During the installation of FusionAnalytics, you will have created an administrator account. To create other accounts, you need to go to FusionAnalytics DataServices > Users tab > Users Summary. Here you will be able to see any existing user accounts and create new ones.

To add an email address to an existing user: Click the Edit button under the username of the account that you want to add an address to. Type an email address into the email field and click the Modify User Details button.

To create a new user: Click the Create A New User button. You must fill in the username and password fields; the first name, last name and email fields are optional. You can always go back and edit these details later.

There is the option to make the account a System User, which means they will have access to all applications (this is the same settings as the administrator account). Once you have clicked Add New User, you can add any application mappings that the user will need. An account with an administrator role can make changes to the application, but an account with a user role can only view the data in a client.

1.2 SERVER SETTINGS

During installation, you will have set the host address and port number of the server for FusionAnalytics. If needed, these settings can be changed under FusionAnalytics DataServices > System tab > Server Settings. This needs to be correct for the reports (and any other background tasks) to run.

The server host field is the server or IP address that FusionAnalytics is running on; the server port is the port that FusionAnalytics is configured to use.

1.3 EMAIL SETTINGS

You will also need to make sure that the email server settings are correct before you can receive any emails from FusionAnalytics. To do this, go to FusionAnalytics DataServices > System tab > Server Settings. These fields need to be set, as any emails that are sent to and from FusionAnalytics use these as the default. This includes the sending of all notification emails.

The mail server field needs to be set to the server or IP address of the server that sends SMTP mail messages; e.g. mail.company.com:25. By default the port number is set to 25, but you can specify a port number after the address if needed; e.g. 127.0.0.1:587. If you need to provide authentication, you need to put this in front of the address: username::25.

1.4 DAILY STATUS REPORTS

The reports are configured in FusionAnalytics DataServices > Scheduled Tasks tab > Create A New Task. You can set the name, how long and how often the task will run. The task will run indefinitely if no end date is specified. There are several options for how often you want the task to run; as these are Daily Status Reports, you probably want to have them recurring daily at a suitable time, e.g. early in the morning when there are no other tasks running.

The Provider Name must be set to DailyStatus. You can then provide particular arguments to the report if needed (see 2.2 receiving reports as emails and 2.3 running reports for a specific date).

2.0 CUSTOMISING YOUR REPORTS

2.1 APPLICATON FILTERS

By making use of the application filters in the FusionAnalytics client, you can make sure you get the most out of the information you receive in your Daily Reports. They allow you to see data specifically for particular parts of your application.

Under the Administrator tab in your FusionAnalytics client, you need to select Manage Applications. Click the Add New Application button; specify an appropriate name and set the filter either by URL or by writing your own specific parameters. The filters allow you to sort the requests from each application by protocol, username, password, hostname, port or by a particular path element.

Once you have added application filters, you must log out of the client and log in again to see the applications listed. You can add as many application filters as you need; these allow you to sort the data to only see requests from particular parts of the application.

2.2 RECEIVING REPORTS AS EMAILS

To send the report straight to your inbox, you must first have an email address set on your user account. To do this, see 1.1 users. The advantage of setting this up is that every time a report is scheduled to run, it will also email a copy to any users that are specified.

Once you have ensured that the required users have email addresses, you will need to create a scheduled task (see 1.4 daily status reports). In the provider arguments section, you will need to put users in the name field and insert your username in the value field.

To send the report to multiple users, in the value field insert the usernames separated by a comma and no spaces; e.g. admin,user1,user2. All these user accounts must have email addresses set, otherwise they will not receive the report.

2.3 RUNNING REPORTS FOR A SPECIFIC DATE

You can also set the reports to run on data from a specific day. When you are creating your scheduled task, add the following provider arguments: date (for the name field) and a UTC time format in milliseconds (for the value field). There are many free UTC calculators available on the Internet to help you calculate this value. From the date entered, the report will show the previous 24 hours.

3.0 RUNNING THE REPORTS

3.1 RUNNING DAILY STATUS REPORTS INSTANTLY

The report will run at the time you have specified, but you can also force it to run at any time by clicking Run Now in the FusionAnalytics DataServices > Scheduled Tasks tab > Scheduled Tasks Summary.

Once the report has run, you will see it in your FusionAnalytics client > Business Metrics > Reports. You can use the timeline to navigate to the reports from previous dates. To open a report, right click the row and select Open Report.

3.2 READING A DAILY STATUS REPORT

By comparing data with the previous day, the Daily Status Reports allow you to see the changes in your server from day to day. This gives you information on each section and what it all means.

Overview: As the name suggests, this section allows you to quickly see vital statistics about the requests that have run in the last 24 hours. The arrows easily show if the change is positive, negative or neutral. For example, a red arrow means a negative change, but this may point up, as an increase may indicate requests are taking longer to complete.

Each attribute also shows the amount of change as a percentage, the delta value, the actual value for the last 24 hours and the value for the previous day (for the 24 prior to the current report). Several rows also list the minimum and maximum requests that occurred between each sample.

System Load Statistics: These graphs show the system and process CPU load and memory usage. If the graphs are showing that the loads or usage is high, this can indicate that the application needs to be looked at. Underneath the graphs, there is also a percentage change from the previous day, with actual and previous day values.

Session Statistics: This gives the recorded number of session and ColdFusion IDs, including the average number of requests that run per ID.

Slowest Requests: This section allows you to easily see which requests are taking the longest to complete. Only the longest 5 requests are shown, but if viewed in a web browser, this can be expanded to show the 20 slowest requests. If the same URLs constantly give slow requests, it may need to be investigated further in the application.

Slowest Requests on Average: Similar to the above section, this allows you to see the slowest requests grouped by URL. It also shows how many times this URL was used in the request count. This section can also be expanded in a web browser to see more requests.

Application Data Overview: If you have application filters configured (see 2.1 application filters), you will see them listed in this section. This gives similar information shown in the overview and session statistics sections, but only counts data that is relevant to that part of the application.

Application JDBC Overview: Similar to the above section, it lists JDBC data that is relevant to each application filter that has been configured (see 2.1 application filters).

Applications: This section divides each configured application filter into a separate sub-section, which lists the overall slowest requests and the slowest requests on average for each one. This is the same as the previous sections on slowest requests and slowest requests on average, but with data relevant to a specific part of the application.

Issue Details

Type: Technote
Issue Number: FNS-1
Components: DailyStatus Report
Environment:
Resolution: Fixed
Added: 09/11/2010 16:17:19
Affects Version:
Fixed Version: 1.0.0
Server:
Platform:
Related Issues: None

[FNS-20] FusionAnalytics Hotfix 1.0.1 Release Notes

Description


FusionAnalytics Rev. 1.0.1


RELEASE NOTES

Status: 22-11-2011

Welcome to FusionAnalytics !

We appreciate your feedback. Please use the web form or send mail to:

These Release Notes describe what is contained in this release, provide
late-breaking news, and list additional documentation for the software.

For additional information on FusionAnalytics, please visit our website at:

https://www.fusion-analytics.com

The help for this product is online, where it can be constantly updated
and refreshed. You can find it here:

https://intergral.atlassian.net/wiki/

For known issues and further support, please see the following web pages:

https://www.fusion-analytics.com/fa/faq.cfm
https://www.fusion-analytics.com/fa/support.cfm

About this update

This update addresses the following bugs:

  • FNS-18 Truncation errors while importing data
  • FNS-19 ‘Value is not set for the parameter number x’ error while importing data

along with some other minor issues, and is also packaged with an upgraded version (1.0.6) of the FusionAnalytics for FusionReactor application. Once you have installed the update you can find the latest application package under [install_directory]/Applications.

You should upgrade your applications to avoid compatibility issues.

How to apply this update to your FusionAnalytics installation

To update your FusionAnalytics installation to Rev. 1.0.1 simply follow the steps below:

  1. Download the Hotfix installer matching your operating system:
    Name MD5
    FusionAnalytics Hotfix installer for Windows ef2eaa8f44a84d7fe485e53b54983af0
    FusionAnalytics Hotfix installer for Windows 64 2f9c92c9cfcc714ee6385dadef71e645
  2. Start the installer and follow the steps to complete the update.
    • You must accept the terms and conditions again before you are able to apply this update.
    • You must select a valid FusionAnalytics installation directory during the update process.

Your FusionAnalytics service will be restarted during the update.

Upgrading your existing 1.0.5 applications to 1.0.6

Follow the steps below to upgrade your 1.0.5 applications to 1.0.6.

  1. Install the FusionAnalytics 1.0.1 update(see below for instructions).
  2. In FADC, navigate to the Application Summary and make sure the application you wish to upgrade is stopped.
  3. Click the Upgrade button
  4. Ensure your application is selected in the list, press the “Choose File” button and select the new application ([install_directory]/Applications/fusionreactor-fadc-1.0.6-DCAPP.zip)
  5. Press Upgrade. FusionAnalytics will now make the necessary changes to your database and application configuration for the new version.
    Please be patient during the upgrade process. The time taken for this process to complete will vary depending on the size of your database!

Note: You can confirm the application update was successful by looking at the Application Summary screen in FADC and checking the Revision column:

Issue Details

Type: Technote
Issue Number: FNS-20
Components: Documentation
Environment:
Resolution: Fixed
Added: 18/11/2011 18:15:15
Affects Version: 1.0.0
Fixed Version: 1.0.1
Server:
Platform:
Related Issues: None

[FNS-9] FusionAnalytics 1.0.0 Release Notes

Description


FusionAnalytics Rev. 1.0.0


RELEASE NOTES

Status: 01-10-2011

Welcome to FusionAnalytics !

We appreciate your feedback. Please use the web form or send mail to:

These Release Notes describe what is contained in this release, provide
late-breaking news, and list additional documentation for the software.

For additional information on FusionAnalytics, please visit our website at:

https://www.fusion-analytics.com

The help for this product is now online, where it can be constantly updated
and refreshed. You can find it here:

https://intergral.atlassian.net/wiki/

For known issues and further support, please see the following web pages:

https://www.fusion-analytics.com/fa/faq.cfm
https://www.fusion-analytics.com/fa/support.cfm

———————————————–

RESOLVED ISSUES 1.0.0

Key Issue Type Summary
FN1 New Feature FusionAnalytics Initial Release

Issue Details

Type: Technote
Issue Number: FNS-9
Components: Setup
Environment:
Resolution: Fixed
Added: 18/08/2011 16:33:20
Affects Version: 1.0.0
Fixed Version: 1.0.0
Server:
Platform:
Related Issues:
  • FNS-22 – FusionAnalytics 1.0.1 Release Notes

[FNS-19] ‘Value is not set for the parameter number x’ error while importing data

Description

Problem Description

Due to a bug in FusionAnalytics 1.0.0 the import of log data targeting a BIGINT column fails if the value parsed from the log line has a length of exactly 10 characters. In such cases an error message is written to the fusionanalytics-datacollector.log and the fusionanalytics-datacollector-errors.log log files as shown in the example below:

...
2011-11-04T17:05:39.998-0400 [FADC-importer-3] ERROR [com.intergral.fusionanalytics.dc.evt.FileMonitorEventHandler] MyApp/myDataCollector/memorysummary.log: 2011-11-04 17:05:39,998 [LINE] 500 [ERROR] "The value is not set for the parameter number 6." [INPUT] "2011-11-04 16:41:50.003 1320439310000 4 1320434053992 29 2415298528 8303607808 8589934592 8303607808 42 135520024 212979712 24313856 318767104 0"
...
2011-11-04T17:05:41.130-0400 [FADC-importer-3] ERROR [com.intergral.fusionanalytics.dc.evt.FileMonitorEventHandler] MyApp/myDataCollector/realtimestats.log: 2011-11-04 17:05:41,130 [LINE] 719 [ERROR] "The value is not set for the parameter number 18." [INPUT] "2011-11-04 16:59:58.072 1320440398072 1 1320434053992 292 0 322.23214285714283 0 0 0 0 0 0 0 0 0 0 6131432480 2172175328 0.0 0 0 1 0 0.9333177780370328 0 0 725 0.0 6683287 0 1 0 0 0 0 0 0 0 0"
...
2011-11-04T17:05:41.369-0400 [FADC-importer-2] ERROR [com.intergral.fusionanalytics.dc.evt.FileMonitorEventHandler] MyApp/myDataCollector/memory-Par-Eden-Space.log: 2011-11-04 17:05:41,369 [LINE] 718 [ERROR] "The value is not set for the parameter number 9." [INPUT] "2011-11-04 17:00:00.005 1320440400001 4 1320434053992 Par-Eden-Space HEAP 0 0 2290614272 2290614272 2290614272 0 0 1 56 1299068648 2290614272 2290614272 2290614272 -1 -1 0 100 2290614272 2290614272 2290614272 2290614272"
...

Note: FADC will write a similar error message if the format of the log line does not have the expected format as defined in the DCML file. This is expected behavior and in this case only skips the line which could not be parsed.

Problem Fix

The problem can be fixed by installing FusionAnalytics Hotfix 1.0.1. Please see FNS-20 for more information.

Issue Details

Type: Technote
Issue Number: FNS-19
Components: DataCollector
Environment:
Resolution: Fixed
Added: 14/11/2011 21:15:13
Affects Version: 1.0.0
Fixed Version: 1.0.1
Server:
Platform:
Related Issues: None